Equipment and Calibration

Equipment history at Sherman Barn

| ALL | | Anemometer || Camera || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Interface || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || RH & Temp || Soil Moisture Probe || Water Level |

SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) ORDER BY b.equip, a.eh_date, field(a.eh_title,'Calibration', 'Removed', 'Installed')

DateSerial No.ModelActionRefNotes
Anemometer
2018-07-11 153802 WM 1590 Installed Anemometer Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2020-07-09 153802 WM 1590 Removed Anemometer Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Camera
2018-07-11 0030F4D2148D SD130BN Installed Camera Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2020-07-09 0030F4D2148D SD130BN Removed Camera Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Data Logger
2018-07-11 47108 CR1000 Installed Data Logger Met Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2019-01-24 47108 CR1000 Serviced Data Logger Met Changed Pakbus address from 1 to 8.
2019-05-28 47108 CR1000 Notes Data Logger Met VX2 may be unreliable. NR01 PRT was drifting constantly until it was re-wired from VX2 to VX3, but that could also have been a wiring issue with another channel.
2020-07-09 47108 CR1000 Removed Data Logger Met Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Forced Diffusion
2018-01-18 20160006 eosFD Disposed none Marked as disposed
Gas Analyzer
2018-07-11 0041 LI-7500A Installed Gas Analyzer CO2/H2O Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2019-01-02 0041 LI-7500A Calibration Lab Last calibration: 2018-07-03 AGC=98 SDM=0 DAC1=0 DAC2=0 Ambient P=101.2kPa, Tair=20.1C, Tdew=3.7C Zero Air at 1400psi, AMP Air 408.97 at 875 Tdewspan=16.00 CO2 zero 0.9966 -> .9953 Offset: -4.19ppm CO2 span 1.0173 -> 1.0194 Offset: -1.25ppm H2O zero 0.8192 -> .8248 Offset: 34.0ppm H2O span 1.0285 -> 1.0312 Offset: -.07ppm Notes: H2O zero offset larger than I expected, but H2O span seems fine.
2018-07-11 TG1-0357 LI-7700 Installed Gas Analyzer CH4 Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2018-10-18 0041 LI-7500A Removed Gas Analyzer CO2/H2O Removed from Sherman Barn for calibration. Replaced by sn 75H-2669.
2019-01-02 0041 LI-7500A Calibration Lab Last calibration: 2018-07-03 AGC=98 SDM=0 DAC1=0 DAC2=0 Ambient P=101.2kPa, Tair=20.1C, Tdew=3.7C Zero Air at 1400psi, AMP Air 408.97 at 875 Tdewspan=16.00 CO2 zero 0.9966 -> .9953 Offset: -4.19ppm CO2 span 1.0173 -> 1.0194 Offset: -1.25ppm H2O zero 0.8192 -> .8248 Offset: 34.0ppm H2O span 1.0285 -> 1.0312 Offset: -.07ppm Notes: H2O zero offset larger than I expected, but H2O span seems fine.
2018-10-18 75H-2669 LI-7500A Installed Gas Analyzer CO2/H2O Installed on Sherman Barn to replace sn 0041 for calibration
2019-04-15 75H-2669 LI-7500A Calibration Lab Last calibration: 2018-10-10 AGC=103.8 SDM=0 DAC1=- DAC2=- Ambient P=100.16kPa, Tair=24.85C, Tdew=6.62C Zero Air 369068 at 1150psi, AMP CA04396 408.97 at 800 Tdewspan=15.99 CO2 zero 0.9188 -> 0.9186 Offset: -1.10ppm CO2 span 1.0106 -> 1.0134 Offset: -1.52ppm H2O zero 0.8992 -> 0.8991 Offset: -0.3ppm H2O span 1.0034 -> 1.0017 Offset: 0.03ppm Notes: Very stable - Joe
2019-01-31 75H-2669 LI-7500A Removed Gas Analyzer CO2/H2O Removed from SB and brought back to the lab for calibration. It was replaced by 75H-2180.
2019-04-15 75H-2669 LI-7500A Calibration Lab Last calibration: 2018-10-10 AGC=103.8 SDM=0 DAC1=- DAC2=- Ambient P=100.16kPa, Tair=24.85C, Tdew=6.62C Zero Air 369068 at 1150psi, AMP CA04396 408.97 at 800 Tdewspan=15.99 CO2 zero 0.9188 -> 0.9186 Offset: -1.10ppm CO2 span 1.0106 -> 1.0134 Offset: -1.52ppm H2O zero 0.8992 -> 0.8991 Offset: -0.3ppm H2O span 1.0034 -> 1.0017 Offset: 0.03ppm Notes: Very stable - Joe
2019-01-31 75H-2180 LI-7500A Installed Gas Analyzer CO2/H2O Installed at SB to replace sn 75H-2669, which was brought back to the lab for calibration.
2019-04-23 75H-2180 LI-7500A Calibration Lab Last calibration: 2019-01-25 AGC=102 SDM= DAC1= DAC2= Ambient P=100.6kPa, Tair=24.7C, Tdew=10.9C Zero Air at 1100psi, AMP Air 408.97 at 700 Tdewspan=16.00 CO2 zero 0.9137 -> .9136 Offset: -.34ppm CO2 span 1.0262 -> 1.0266 Offset: -.2ppm H2O zero 0.8891 -> .8886 Offset: -3.0ppm H2O span 1.0199 -> 1.0236 Offset: -.07ppm Notes:
2019-04-11 TG1-0357 LI-7700 Calibration Gas Analyzer CH4 Calibration Location: Sherman Barn Last calibration: 2018-07-10 RSSI=70%, Optical RH=3% Ambient P=101.9kPa, Tair=16.5C Zero Air M4002 at 1800psi, AMP CA03923 3.121 at 1800 CH4 Zero Offset: 0.035ppm CH4 Span Offset: -0.002ppm Notes: Windy 3m/s to 7.5m/s
2019-04-18 75H-2180 LI-7500A Removed Gas Analyzer CO2/H2O Removed from SB and brought back to the lab for calibration. It was replaced by sn 75H-2669.
2019-04-23 75H-2180 LI-7500A Calibration Lab Last calibration: 2019-01-25 AGC=102 SDM= DAC1= DAC2= Ambient P=100.6kPa, Tair=24.7C, Tdew=10.9C Zero Air at 1100psi, AMP Air 408.97 at 700 Tdewspan=16.00 CO2 zero 0.9137 -> .9136 Offset: -.34ppm CO2 span 1.0262 -> 1.0266 Offset: -.2ppm H2O zero 0.8891 -> .8886 Offset: -3.0ppm H2O span 1.0199 -> 1.0236 Offset: -.07ppm Notes:
2019-04-18 75H-2669 LI-7500A Installed Gas Analyzer CO2/H2O Installed at SB to replace sn 75H-2180, which was brought back to the lab for calibration.
2019-08-01 75H-2669 LI-7500A Calibration Lab Last calibration: 2019-04-15 AGC=102.6 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=22.7C, Tdew=14.1C Zero Air at 975psi, AMP CA4396 408.97 at 800 Tdewspan=20.00 CO2 zero 0.9186 -> .9178 Offset: -3.12ppm CO2 span 1.0134 -> 1.0125 Offset: .53ppm H2O zero 0.8991 -> .9019 Offset: 17.8ppm H2O span 1.0017 -> 1.015 Offset: -.3ppm Notes: When SS was 102.6, I reset it to 100. I uploaded the the calibration file from 2018-10-24 and copied in the manual coefficients for CO2 span, CO2 zero, H2O span, and H2O zero from the database's record of the most recent calibration on 2019-04-15.
2019-07-25 75H-2669 LI-7500A Removed Gas Analyzer CO2/H2O Removed from SB and brought back to the lab for calibration. it was replaced by sn 75H-2667.
2019-08-01 75H-2669 LI-7500A Calibration Lab Last calibration: 2019-04-15 AGC=102.6 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=22.7C, Tdew=14.1C Zero Air at 975psi, AMP CA4396 408.97 at 800 Tdewspan=20.00 CO2 zero 0.9186 -> .9178 Offset: -3.12ppm CO2 span 1.0134 -> 1.0125 Offset: .53ppm H2O zero 0.8991 -> .9019 Offset: 17.8ppm H2O span 1.0017 -> 1.015 Offset: -.3ppm Notes: When SS was 102.6, I reset it to 100. I uploaded the the calibration file from 2018-10-24 and copied in the manual coefficients for CO2 span, CO2 zero, H2O span, and H2O zero from the database's record of the most recent calibration on 2019-04-15.
2019-07-25 75H-2667 LI-7500A Installed Gas Analyzer CO2/H2O Installed at SB to replace sn 75H-2669, which was brought back to the lab for calibration.
2019-11-12 75H-2667 LI-7500A Calibration Lab Last calibration: 2019-07-24 AGC=101.4 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=26.2C, Tdew=10.9C Zero Air at 950psi, AMP CA4396 408.97 at 700 Tdewspan=16.00 CO2 zero 0.9413 -> .9419 Offset: 2.32ppm CO2 span 1.0158 -> 1.019 Offset: -1.67ppm H2O zero 0.8363 -> .8384 Offset: 12.8ppm H2O span 1.0222 -> 1.0239 Offset: -.03ppm Notes:
2019-09-04 TG1-0357 LI-7700 Upgrade Gas Analyzer CH4 We updated the 7700 firmware from v1.0.21 to v1.0.27. To do this we had to change the 7700’s IP address to 192.168.2.77 – it was still at the default 169 subnet
2019-10-31 TG1-0357 LI-7700 Calibration Gas Analyzer CH4 Calibration Location: Sherman Barn Last calibration: 2019-04-11 RSSI=68%, Optical RH=8% Ambient P=102.8kPa, Tair=12.1C Zero Air at 1000psi, AMP CA03923 3.121 at 1050 CH4 Zero Offset: 0.020ppm CH4 Span Offset: -0.011ppm Notes: Power was out earlier this week.
2019-10-31 75H-2667 LI-7500A Removed Gas Analyzer CO2/H2O Removed from Sherman Barn for calibration. Replaced by sn 75H-2668.
2019-11-12 75H-2667 LI-7500A Calibration Lab Last calibration: 2019-07-24 AGC=101.4 SDM= DAC1= DAC2= Ambient P=100.7kPa, Tair=26.2C, Tdew=10.9C Zero Air at 950psi, AMP CA4396 408.97 at 700 Tdewspan=16.00 CO2 zero 0.9413 -> .9419 Offset: 2.32ppm CO2 span 1.0158 -> 1.019 Offset: -1.67ppm H2O zero 0.8363 -> .8384 Offset: 12.8ppm H2O span 1.0222 -> 1.0239 Offset: -.03ppm Notes:
2019-10-31 75H-2668 LI-7500A Installed Gas Analyzer CO2/H2O Installed at Sherman Barn to replace sn 75H-2667 for calibration.
2020-02-11 75H-2668 LI-7500A Calibration Lab Last calibration: 2019-10-30 AGC=100.4 SDM=0 DAC1=- DAC2=- Ambient P=100.8kPa, Tair=26.9C, Tdew=-1.59C Zero Air at 800psi, AMP CA04396 408.97 at 550 Tdewspan=16.0 CO2 zero 0.9393 -> 0.9393 Offset: -0.1ppm CO2 span 1.016 -> 1.0171 Offset: -0.94ppm H2O zero 0.9096 -> 0.9072 Offset: 2.7ppm H2O span 1.0143 -> 1.0147 Offset: -0.01ppm Notes: Ambient air very dry
2020-02-06 75H-2668 LI-7500A Removed Gas Analyzer CO2/H2O Removed from Sherman Barn and brought back to the lab for calibration. Replaced by sn 75H-2669.
2020-02-11 75H-2668 LI-7500A Calibration Lab Last calibration: 2019-10-30 AGC=100.4 SDM=0 DAC1=- DAC2=- Ambient P=100.8kPa, Tair=26.9C, Tdew=-1.59C Zero Air at 800psi, AMP CA04396 408.97 at 550 Tdewspan=16.0 CO2 zero 0.9393 -> 0.9393 Offset: -0.1ppm CO2 span 1.016 -> 1.0171 Offset: -0.94ppm H2O zero 0.9096 -> 0.9072 Offset: 2.7ppm H2O span 1.0143 -> 1.0147 Offset: -0.01ppm Notes: Ambient air very dry
2020-02-06 75H-2669 LI-7500A Installed Gas Analyzer CO2/H2O Installed at Sherman Barn to replace sn 75H-2668, which was brought back to the lab for calibration.
2020-05-22 75H-2669 LI-7500A Calibration Lab Last calibration: 2020-02-04 AGC=100.7 SDM=0 DAC1=- DAC2=- Ambient P=100.2kPa, Tair=23.5C, Tdew=8.3C Zero Air at 750psi, AMP CA04396 408.97 at 600 Tdewspan=16.0 CO2 zero 0.9184 -> 0.9185 Offset: 0.44ppm CO2 span 1.016 -> 1.0124 Offset: 1.78ppm H2O zero 0.9006 -> 0.8999 Offset: -4.3ppm H2O span 1.0101 -> 1.0094 Offset: 0.01ppm Notes:
2020-05-21 TG1-0357 LI-7700 Calibration Gas Analyzer CH4 Calibration Location: Sherman Barn Last calibration: 2019-10-31 RSSI=80%, Optical RH=12% Ambient P=101.6kPa, Tair=19.2C Zero Air at 800psi, AMP CA3923 3.121 at 800 CH4 Zero Offset: 0.036ppm CH4 Span Offset: 0.036ppm Notes: Breezy day
2020-05-21 75H-2669 LI-7500A Removed Gas Analyzer CO2/H2O Removed from Sherman Barn and brought back to the lab for calibration. Replaced by sn 75H-2668.
2020-05-22 75H-2669 LI-7500A Calibration Lab Last calibration: 2020-02-04 AGC=100.7 SDM=0 DAC1=- DAC2=- Ambient P=100.2kPa, Tair=23.5C, Tdew=8.3C Zero Air at 750psi, AMP CA04396 408.97 at 600 Tdewspan=16.0 CO2 zero 0.9184 -> 0.9185 Offset: 0.44ppm CO2 span 1.016 -> 1.0124 Offset: 1.78ppm H2O zero 0.9006 -> 0.8999 Offset: -4.3ppm H2O span 1.0101 -> 1.0094 Offset: 0.01ppm Notes:
2020-05-21 75H-2668 LI-7500A Installed Gas Analyzer CO2/H2O Installed at Sherman Barn to replace sn 75H-2669 for calibration.
2020-07-09 75H-2668 LI-7500A Removed Gas Analyzer CO2/H2O Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 TG1-0357 LI-7700 Removed Gas Analyzer CH4 Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Heat Flux Plate
2018-07-11 6342 HFP01 Installed Heat Flux Plate A Installed at Sherman Barn to the NW of the scaffolding at -2cm. This is the initial set up of the site.
2018-07-11 6491 HFP01 Installed Heat Flux Plate B Installed at Sherman Barn to the W of the scaffolding at -2cm. This is the initial set up of the site.
2018-07-11 6498 HFP01 Installed Heat Flux Plate C Installed at Sherman Barn to the SW of the scaffolding at -2cm. This is the initial set up of the site.
2020-07-09 6342 HFP01 Removed Heat Flux Plate A Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus. This sensor was in a northern position relative to the other soil profiles.
2020-07-09 6491 HFP01 Removed Heat Flux Plate B Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus. This sensor was in the middle soil profile, located between the north and south profile. The sensor was very near the surface, with only litter covering it.
2020-07-09 6498 HFP01 Removed Heat Flux Plate C Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus. This sensor was in the southern soil profile relative to the other two profiles.
Interface
2018-07-11 6763 NL115 Installed Interface NL115 Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2018-07-11 AIU-1557 LI-7550 Installed Interface LI-7550 Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2020-05-21 AIU-1557 LI-7550 Upgrade Interface LI-7550 Upgraded firmware from 8.5.0 to 8.8.32. It should have this update from version 8.8.15 to help with our 7550/7700 clock sync errors: "Revamped code that logs LI-7700 methane data with CO2 data in order to prevent missing LI-7700 data."
2020-07-09 6763 NL115 Removed Interface NL115 Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 AIU-1557 LI-7550 Removed Interface LI-7550 Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Multiplexer
2018-07-11 11662 AM16/32B Installed Multiplexer Met Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2018-07-11 6767 AM25T Installed Multiplexer Thermocouples Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2019-05-28 11662 AM16/32B Notes Multiplexer Met Channel 28 and 32 are probably bad (see field notes from SB 2019-04-11).
2020-07-09 11662 AM16/32B Removed Multiplexer Met Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 6767 AM25T Removed Multiplexer Thermocouples Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Narrow Band
2018-07-11 913003006 SRS-Pi PRI Installed Narrow Band PRI Incoming Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2018-07-11 913003007 SRS-Pi PRI Installed Narrow Band PRI Reflected Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2018-07-11 882103036 SRS-Ni NDVI Installed Narrow Band NDVI Incoming Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2018-07-11 882103061 SRS-Ni NDVI Installed Narrow Band NDVI Reflected Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2020-07-09 913003006 SRS-Pi PRI Removed Narrow Band PRI Incoming Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 913003007 SRS-Pi PRI Removed Narrow Band PRI Reflected Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 882103036 SRS-Ni NDVI Removed Narrow Band NDVI Incoming Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 882103061 SRS-Ni NDVI Removed Narrow Band NDVI Reflected Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Net Radiometer
2018-07-11 1570 NR01 Installed Net Radiometer 4-way Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2020-07-09 1570 NR01 Removed Net Radiometer 4-way Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
PAR Sensor
2018-07-11 110339 PQS 1 Installed PAR Sensor Incoming Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2018-07-11 110338 PQS 1 Installed PAR Sensor Reflected Installed at Sherman Barn on the radiation boom just outside the southwest corner of the cow fence. This is the initial set up of the site.
2020-07-09 110339 PQS 1 Removed PAR Sensor Incoming Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
2020-07-09 110338 PQS 1 Removed PAR Sensor Reflected Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Precipitation
2018-07-11 49187-109 TE525MM Installed Precipitation Installed at Sherman Barn on a T-post in the northwest corner of the cow fence. This is the initial set up of the site.
2018-10-18 49187-109 TE525MM Calibration Precipitation Got 94 of 100 tips - adjusted by a total of 3.5 turns CCW (screws were loose, so this total is suspicious; should have been a CW adjustment when all was said and done) 2018-10-18: Got 94 of 100 tips - adjusted by 0.5 turns CW. 2018-12-18: Got 117 of 100 tips - adjusted by 1 turn CCW, but screws feel very loose. 2019-01-03: Got 118 of 100 tips - adjusted by 3 turns CCW. (previous adjustment of 1 turn CCW did not seem to make a difference). 2019-01-24: Got 100 of 100 tips! No adjustments made.
2019-10-31 49187-109 TE525MM Calibration Precipitation After cleaning the tipping bucket we connected it to a CR23x and dripped 475ml of water through the bucket which should result in 100tips. We got 90 tips. We turned its set screws two full rotations CW.
2019-11-19 49187-109 TE525MM Tested Precipitation Plug tipping bucket into the calibration CR23x and dripped 475ml of water through the bucket which should result in 100tips. Got 104 tips and turned both set screws 1/2 turn CCW.
2020-07-09 49187-109 TE525MM Removed Precipitation Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
RH & Temp
2018-07-11 U3030041 HMP45AC Installed RH & Temp Installed at Sherman Barn on the scaffolding frame in the southwest corner of the cow fence. This is the initial set up of the site.
2019-11-19 U3030041 HMP45AC Removed RH & Temp Removed from SB and brought back to the lab for further testing. This sensor had some spikes in late September and starting mid-Nov hovered around 2degC.
2019-12-16 T2130005 HMP45AC Installed RH & Temp Installed at SB to replace sn sn U3030041, which had been removed and brought back to the lab for testing.
2020-07-09 T2130005 HMP45AC Removed RH & Temp Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Soil Moisture Probe
2018-07-11 377/008 ML2x Installed Soil Moisture Probe A Installed at Sherman Barn to the NW of the scaffolding at -5cm. This is the initial set up of the site.
2018-07-11 54/016 ML2x Installed Soil Moisture Probe B Installed at Sherman Barn to the W of the scaffolding at -5cm. This is the initial set up of the site.
2018-07-11 377/010 ML2x Installed Soil Moisture Probe C Installed at Sherman Barn to the SW of the scaffolding at -5cm. This is the initial set up of the site.
2020-07-09 377/008 ML2x Removed Soil Moisture Probe A Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus. This sensor was near the surface in the northern profile (relative to the other 2 profiles).
2020-07-09 54/016 ML2x Removed Soil Moisture Probe B Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus. This sensor was near the surface, between the other two soil profiles.
2020-07-09 377/010 ML2x Removed Soil Moisture Probe C Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus. This sensor was just below the surface and in the southern profile (relative to the other 2 profiles).
Water Level
2018-07-11 20010046 CS451 Installed Water Level Installed at Sherman Barn just to the north of the scaffolding. This is the initial set up of the site.
2020-02-06 20010046 CS451 Notes Water Level Camilo measured water level: Distance from top of well to water level: 88.1cm (2.89ft) Distance from top of well to ground: 24.7cm (0.81ft) Distance from top of well to sensor: ?? Sensor psi reading: 0.653 psi ~ 46cm
2020-07-09 20010046 CS451 Removed Water Level Removed from Sherman Barn with its decommissioning and given to Sabina of Hydrofocus. The DWR grant ended at the end of June 2020, and Bryan requested we hand off a tower to Hydrofocus.
Export to BADM