Equipment and Calibration History
History for Apogee S2-431 1061
Rec No. | Date | Loc From | Title | Loc To | Notes |
---|---|---|---|---|---|
4691 | 2020-08-24 | Factory none | Disposed | Disposed none | Apogee found manufacturing defects and will send us a replacement NDVI sensor. |
4557 | 2020-07-13 | Lab none | Tested | Lab none | I tried to talk to the sensor with the new Apogee SDI-12 to USB dongle and Apogee software - no luck. The same method worked just fine foe the new NDVI sensors. Next will be to return them to Apogee for evaluation. |
4524 | 2020-06-11 | Lab none | Tested | Lab none | The two red/far red sensors stopped working on the BA tower. I tested them on the CR1000 in the lab running the BA program and still got no response. I tried the CR1000 terminal to talk to them over SDI-12 and got nothing trying both C1 and C3 ports. I will get a USB to SDI-12 from Apogee soon and will try again with that. |
4465 | 2020-05-19 | Bouldin Alfalfa Narrow Band NDVI Incoming Test | Removed | Lab none | Removed from BA because it was sending NANs and brought back to the lab for testing. |
4431 | 2020-04-17 | Lab none | Installed | Bouldin Alfalfa Narrow Band NDVI Incoming Test | Installed at BA in the incoming position. |
4413 | 2020-04-14 | Lab none | Maintenance | Lab none | SDI-12 address changed from factory default of 0 (zero) to K |