Equipment history at Vaira| ALL | | Anemometer || Battery Bank || Camera || CO2 Probe || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Interface || LED sensor || Moisture Point || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Pyranometer || Radio || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Weather Station |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
Soil Moisture Probe | |||||
2022-05-26 | 2677 | SoilVUE10 | Installed | Soil Moisture Probe I Profile | Installed 5.3m at heading 220deg from the met box about a meter outside the fence near the gate. |
2022-05-26 | 2679 | SoilVUE10 | Installed | Soil Moisture Probe H Profile | Installed 7.7m at heading 26deg from the met box near the solar panels and the old Moisture Point probe location |
2022-05-26 | 2690 | SoilVUE10 | Installed | Soil Moisture Probe F Profile | Installed at 5.4m at heading 345deg from the met box about halfway between the eddy tower and radiation tower |
2002-08-01 | 54/007 | ML2x | Location | Soil Moisture Probe E | From a field note by Liu Kang, this sensor is in the fifth location at Vaira. It is noted that sn 54/020 was listed in this location previously but it is unknown when the swap was made. |
2004-10-22 | 54/007 | ML2x | Removed | Soil Moisture Probe E | Removed from Vaira due to low readings. Replaced by sn 64/072 |
2002-08-01 | 54/011 | ML2x | Location | Soil Moisture Probe B | From a field note by Liu Kang. |
2022-02-09 | 54/011 | ML2x | Location | Soil Moisture Probe B | Wired as Theta soil moisture #2 |
2000-10-07 | 54/015 | ML2x | Installed | Soil Moisture Probe A | Installed at -20cm with the intial set up of the Vaira site. Moved on 11-04 |
2000-11-04 | 54/015 | ML2x | Moved | Soil Moisture Probe A | Moved from testing location. New location is at -20cm |
2002-08-01 | 54/015 | ML2x | Location | Soil Moisture Probe A | From a field note by Liu Kang. |
2022-02-09 | 54/015 | ML2x | Location | Soil Moisture Probe A | Wired as Theta soil moisture #1 |
2000-10-07 | 54/016 | ML2x | Installed | Soil Moisture Probe B | Installed at -10cm with the intial set up of the Vaira. Moved on 11-04 |
2000-11-04 | 54/016 | ML2x | Moved | Soil Moisture Probe B | Moved from testing location. New location is at -10cm |
2000-10-07 | 54/017 | ML2x | Installed | Soil Moisture Probe C | Installed at -10cm with the intial set up of the Vaira site. Moved on 11-04 |
2000-11-04 | 54/017 | ML2x | Moved | Soil Moisture Probe C | Moved from testing location. New location is at -10cm |
2002-08-01 | 54/017 | ML2x | Location | Soil Moisture Probe C | From a field note by Liu Kang. |
2022-02-09 | 54/017 | ML2x | Location | Soil Moisture Probe C | Wired as Theta soil moisture #3 |
2000-10-07 | 54/019 | ML2x | Installed | Soil Moisture Probe D | Installed with the setup of the site, initially at the soil surface - moved on 11-04 |
2000-11-04 | 54/019 | ML2x | Moved | Soil Moisture Probe D | Moved from testing location. New location is at 0cm |
2002-08-01 | 54/019 | ML2x | Location | Soil Moisture Probe D | From a field note by Liu Kang. |
2022-02-09 | 54/019 | ML2x | Location | Soil Moisture Probe D | Wired as Theta soil moisture #4 |
2000-10-07 | 54/020 | ML2x | Installed | Soil Moisture Probe E | Installed with the setup of the site, initially at the soil surface - moved on 11-04 |
2000-11-04 | 54/020 | ML2x | Moved | Soil Moisture Probe E | Moved from the surface to -20cm |
2000-12-03 | 54/020 | ML2x | Repair | Soil Moisture Probe E | Found with cable chewed by cows. Cable spliced and seems to be working. |
2004-10-22 | 64/072 | ML2x | Installed | Soil Moisture Probe E | Installed at Vaira to replace sn 54/007 that was reading low. |
2022-02-09 | 64/072 | ML2x | Location | Soil Moisture Probe E | Wired as Theta soil moisture #5 |