Equipment and Calibration
Equipment history at Bouldin Corn| ALL | | Air Quality Sensor || Anemometer || Barometer || Camera || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Infrared Temperature || Interface || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Water Level || Weather Station |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
PAR Sensor | |||||
2020-05-29 | 030381 | PAR-LITE | Installed | PAR Sensor Under-B | I stalled about 10cm above the ground near the picams to measure under canopy PAR |
2020-08-05 | 030381 | PAR-LITE | Removed | PAR Sensor Under-B | Removed from under the canopy at Bouldin Corn. The corn has reached maximum growth continued measurements of questionable use. |
2020-05-29 | 040412 | PAR-LITE | Installed | PAR Sensor Under-A | I stalled about 10cm above the ground near the picams to measure under canopy PAR |
2020-08-05 | 040412 | PAR-LITE | Removed | PAR Sensor Under-A | Removed from under the canopy at Bouldin Corn. The corn has reached maximum growth continued measurements of questionable use. |
2017-04-26 | 140441 | PQS 1 | Installed | PAR Sensor Reflected | Installed in the outgoing position at the Bouldin Corn site with the initial set up of the tower. |
2019-12-02 | 140441 | PQS 1 | Removed | PAR Sensor Reflected | Removed from Bouldin Corn site and brought back to the lab after the tower fell down during a rain/wind storm on 2019-11-26. |
2019-12-13 | 140441 | PQS 1 | Installed | PAR Sensor Reflected | Re-installed at Bouldin Corn in outgoing position after re-assembling tower. |
2021-01-29 | 140441 | PQS 1 | Removed | PAR Sensor Reflected | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
2021-02-03 | 140441 | PQS 1 | Installed | PAR Sensor Reflected | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
2017-04-26 | 140453 | PQS 1 | Installed | PAR Sensor Incoming | Installed in the incoming position at the Bouldin Corn site with the initial set up of the tower. |
2019-12-02 | 140453 | PQS 1 | Removed | PAR Sensor Incoming | Removed from Bouldin Corn site and brought back to the lab after the tower fell down during a rain/wind storm on 2019-11-26. |
2019-12-13 | 140453 | PQS 1 | Installed | PAR Sensor Incoming | Re-installed at Bouldin Corn in incoming position after re-assembling tower. |
2021-01-29 | 140453 | PQS 1 | Removed | PAR Sensor Incoming | Removed due to the tower falling over in the storm near midnight on 2021-01-26/27. Completely submerged |
2021-02-03 | 140453 | PQS 1 | Installed | PAR Sensor Incoming | Reinstalled on the BC tower after cleaning and inspection in the lab after being removed after the tower fell last week |
2017-07-14 | 140456 | PQS 1 | Installed | PAR Sensor Diffuse | Installed at Bouldin Corn tower as part of a diffuse PAR sensor |
2019-12-02 | 140456 | PQS 1 | Removed | PAR Sensor Diffuse | Removed from Bouldin Corn site and brought back to the lab after the tower fell down during a rain/wind storm on 2019-11-26. |
2019-12-13 | 140456 | PQS 1 | Installed | PAR Sensor Diffuse | Re-installed at Bouldin Corn after re-assembling tower as part of a diffuse PAR sensor. |