Equipment and Calibration

Equipment history at Hill Slough

| ALL | | Anemometer || Battery Bank || Camera || CO2 Probe || Conductivity Sensor || Data Logger || DO Sensor || Fluorometer || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Interface || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || pH ORP || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level || Wiper |

SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date

Date Serial No. Model Action Ref Notes
Interface
2022-07-13 22C103416 EXO2 Installed Water Level Installed at HS in the channel off of the boardwalk, about 30m east of the tower. We installed the sonde near low tide to ensure it would stay underwater at all times.
2022-09-16 22C103416 EXO2 Removed Removed from the channel at Hill Slough. It was brought back to the lab for cleaning, calibration, and to convert its output to SDI-12 so we can wire it to the channel CR23X.
2022-09-29 22C103416 EXO2 Installed Water Level Installed in the channel at Hill Slough. The sonde is now wired to the CR23X, which queries it for data every 10sec. The sonde is measureing and storing data internally every 5min.
2023-01-03 22C103416 EXO2 Removed Removed from Hill Slough channel and brought back to the lab for calibration.
2023-01-06 22C103416 EXO2 Installed Water Level Installed in the channel at Hill Slough (same height as before) after calibrating in the lab yesterday. Installed without batteries in the sonde.
2023-04-25 22C103416 EXO2 Removed Removed from HS channel for routine calibration
2023-05-09 22C103416 EXO2 Installed Water Level Installed in the channel at Hill Slough (same height as before)
2023-08-24 22C103416 EXO2 Installed Water Level Reinstalled after quarterly cleaning and calibration
2023-10-11 22C103416 EXO2 Removed Removed for inspection in the lab because turbidy/fDOM/ph/ORP look weird
2023-10-18 22C103416 EXO2 Installed Water Level Installed in the Hill Slough channel after calibration in the lab. The whole sonde was raised about 20cm to keep it out of the mud.
2024-01-18 22C103416 EXO2 Removed Water Level Removed from HS channel and brought back to the lab for routine calibration
2024-01-25 22C103416 EXO2 Installed Water Level Installed in the Hill Slough channel after calibration
2024-04-04 22C103416 EXO2 Removed Water Level Removed from the Hill Slough channel and brought back to the lab for calibration (and to install the new auto wiper that arrived)
2024-04-10 22C103416 EXO2 Installed Interface EXO Reinstalled at the HS channel after regular lab cleaning and calibration
2024-07-16 22C103416 EXO2 Removed Interface EXO Removed from the HS channel and brought back to the lab for routine calibration
2024-07-23 22C103416 EXO2 Installed Interface EXO Installed in the Hill Slough channel after calibration. Sonde is in the air during low tide.
2024-10-17 22C103416 EXO2 Removed Interface EXO Removed from the Hill Slough channel and brought back to the lab for routine calibration
2024-10-24 22C103416 EXO2 Installed Interface EXO Installed in the HS channel after calibration
2021-03-11 AIU-0650 LI-7550 Installed Interface LI-7550 Installed at Hill Slough with site setup. Renamed from SWTT-0650 to HS-0650.
2021-03-25 AIU-0650 LI-7550 Upgrade Interface LI-7550 The firmware was upgraded from v8.5.5 to v8.8.32. No problems noticed.