Equipment history at Hill Slough| ALL | | Anemometer || Battery Bank || Camera || CO2 Probe || Conductivity Sensor || Data Logger || DO Sensor || Fluorometer || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Interface || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || pH ORP || Precipitation || Range Finder || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Water Level || Wiper |
SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date
Date | Serial No. | Model | Action | Ref | Notes |
---|---|---|---|---|---|
Conductivity Sensor | |||||
2023-05-09 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Installed in the channel at Hill Slough (same height as before) after calibration |
2023-08-24 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Reinstalled after quarterly cleaning and calibration |
2023-10-11 | 23D104030 | EXO Wiped Cond/Temp | Removed | Conductivity Sensor | Removed for inspection in the lab because turbidy/fDOM/ph/ORP look weird |
2023-10-18 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Installed in the Hill Slough channel after calibration in the lab. The whole sonde was raised about 20cm to keep it out of the mud. |
2024-01-18 | 23D104030 | EXO Wiped Cond/Temp | Removed | Conductivity Sensor | Removed from HS channel and brought back to the lab for routine calibration |
2024-01-25 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Installed in the Hill Slough channel after calibration |
2024-04-04 | 23D104030 | EXO Wiped Cond/Temp | Removed | Conductivity Sensor | Removed from the Hill Slough channel and brought back to the lab for calibration (and to install the new auto wiper that arrived) |
2024-04-10 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Reinstalled at the HS channel after regular lab cleaning and calibration |
2024-07-16 | 23D104030 | EXO Wiped Cond/Temp | Removed | Conductivity Sensor | Removed from the HS channel and brought back to the lab for routine calibration |
2024-07-23 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Installed in the Hill Slough channel after calibration. Sonde is in the air during low tide. |
2024-10-17 | 23D104030 | EXO Wiped Cond/Temp | Removed | Conductivity Sensor | Removed from the Hill Slough channel and brought back to the lab for routine calibration |
2024-10-24 | 23D104030 | EXO Wiped Cond/Temp | Installed | Conductivity Sensor | Installed in the HS channel after calibration |