| ALL | | Anemometer || Battery Bank || Camera || CO2 Probe || Data Logger || Forced Diffusion || Gas Analyzer || Heat Flux Plate || Interface || LED sensor || Moisture Point || Multiplexer || Narrow Band || Net Radiometer || PAR Sensor || Precipitation || Pyranometer || Radio || RH & Temp || Soil Moisture Probe || Solar Controller || Solar Panel || Weather Station |

SELECT a.recno, a.eh_date, a.eh_loc1, a.eh_loc2, IF(a.eh_loc2=:loc, a.eh_locref2, a.eh_locref1) AS ref, a.eh_locref2, a.eh_title, a.eh_notes, a.eh_id, b.serialno, b.equip, b.modelno FROM equiphist a INNER JOIN equiplist b ON a.eh_id=b.recno WHERE (a.eh_loc1=:loc1 OR a.eh_loc2=:loc2) AND b.equip=:eq ORDER BY b.serialno, a.eh_date

Date Serial No. Model Action Ref Notes
Anemometer
2000-10-22 000019 WMP 1352 Installed Anemometer Installed on the Vaira Tower with the initial setup of the site.
2001-01-05 000019 WMP 1352 Removed Anemometer Removed from the Vaira Tower due to going off scale at midday. Replaced by sn 000024
2005-01-27 000023 WMP 1352 Installed Anemometer Installed at Vaira to replace current sonic - no reason given. Two headings given: 0 and 260 magnetic. Unclear which is new heading and which is old.
2001-01-05 000024 WMP 1352 Installed Anemometer Installed on the Vaira Tower to replace sn 000019 that was going off scale at midday.
2002-04-11 000024 WMP 1352 Removed Anemometer Removed from Vaira for calibration. Replaced by sn 000028.
2002-04-11 000028 WMP 1352 Installed Anemometer Installed at Vaira to replace sn 000024 for calibration.
2002-04-18 000028 WMP 1352 Location Anemometer Location noted in fieldnotes
2005-01-27 000028 WMP 1352 Removed Anemometer Removed from Vaira to be replaced by another sonic - no reason given. Two headings given: 0 and 260 magnetic. Unclear which is new heading and which is old.
2014-04-08 000028 WMP 1352 Location Anemometer Current location of this instrument and probably back to before 2008
2017-05-24 000028 WMP 1352 Removed Anemometer Removed from the Vaira Tower. Replaced by the new Licor GHG system from Ameriflux.
2024-02-09 022365416 SONIC-ANEMO-SPE10 Installed Weather Station B Accessory for the Arable Mark 4 sn D006920.
2017-04-10 153805 WM 1590 Installed Added to the Vaira eddy tower for the Ameriflux inter-comparison and the transition to newer LI-7500A eddy systems.
2017-05-11 153805 WM 1590 Removed Removed from Vaira because the Ameriflux intercomparison finished and because we received new 7500A and sonics from Ameriflux. This sonic was replaced with brand new sonic from Ameriflux, sn 170524.
2017-05-11 170524 WM 1590 Installed Installed at Vaira to replace sn 153805.