East End (362) 2016-12-27 09:00:00 Joe Verfaillie Restarted the computer, upgraded LoggerNet
East End (356) 2016-12-21 12:30:00 Elke Eichelmann Regular data collection, redeployed forerunner dissolved CO2 probe, swapped LI7500
East End (341) 2016-12-06 13:30:00 Joe Verfaillie Cold and windy, standard data collection, checked on computer - some problem auto collecting from CR1000
East End (326) 2016-11-21 09:15:00 Joe Verfaillie Troubleshot power problem, removed EosGP CO2 probe, knocked down cattails under tower, replace HMP60 fan, Collected data
East End (322) 2016-11-17 08:30:00 Joe Verfaillie Installed network interface for CR1000, Errors on CR1000 probably due to conductivity sensor - disconnected.
East End (321) 2016-11-16 10:30:00 Joe Verfaillie Reinstalled computer system with network switch, reconnected sensors to CR1000.
East End (313) 2016-11-08 11:00:00 Joe Verfaillie Ants in data logger box, CR1000 not running mostly restored, remove computer system, lots or spider webs and cattail fluff in eddy sensors.
East End (300) 2016-10-26 12:05:00 Elke Eichelmann Regular data collection, redeployed dissolved oxygen probe, water level low
East End (285) 2016-10-11 12:30:00 Joe Verfaillie Calibrated 7700, examined PAR and DO sensors, water level low, normal data collection, tested rain sensor
East End (273) 2016-09-29 11:20:00 Joe Verfaillie Measured reflectance, installed compute stick, modem and Stardot, remove Canon
East End (266) 2016-09-22 13:30:00 Joe Verfaillie Tried to install compute stick and phenocam, updated CR1000 program.
East End (257) 2016-09-13 11:50:00 Elke Eichelmann Swapped LI7500, took pressure sensor in to lab, leveled net radiometer and PAR sensors
East End (244) 2016-08-31 12:00:00 Joe Verfaillie Swapped 7500, fixed HMP60 fan, wetland beginning to turn brown.
East End (225) 2016-08-12 12:00:00 Alison Haddad Normal data collection, LI7700 very dirty
East End (214) 2016-08-01 10:10:00 Elke Eichelmann Measured water level height, LI7700 auto clean initially not working and was fixed, normal data collection.
East End (202) 2016-07-20 13:20:00 Alison Haddad Camera program wasn’t running, changed LI7700 thermocouple, regular data collection
East End (188) 2016-07-06 12:50:00 Alison Haddad Measured depth of DO and CO2 probes, regular data collection, took spectral
East End (176) 2016-06-24 13:00:00 Joe Verfaillie 7700 fw tc broken, replace 7700 tubing, removed flakey Vaisala air pressure sensor
East End (158) 2016-06-06 13:55:00 Alison Haddad Regular data collection, spectral, replaced LI7500 base screw
East End (145) 2016-05-24 11:46:00 Alison Haddad swapped 7500 for calibration, lost a 7500 base screw, regular data collection, water level still a little low.
East End (133) 2016-05-12 10:45:00 Elke Eichelmann Regular data collection, did spectral, water level still low
East End (119) 2016-04-28 11:30:00 Elke Eichelmann Standard data collection, water level very low, took spectral measurements.
East End (104) 2016-04-13 12:30:00 Elke Eichelmann Calibrated LI7700, no GHG data recorded over past two weeks
East End (89) 2016-03-29 11:10:00 Patty Oikawa Wasps in reservoir, otherwise normal data download
East End (84) 2016-03-24 09:00:00 Joe Verfaillie Swapped solar system batteries, Licor clock 30 min ahead - fixed, was reservoir empty - filled.
East End (68) 2016-03-08 10:46:00 Patty Oikawa Power losses still occurring, conductivity probe looked ok, normal data download, check sonic next time
East End (56) 2016-02-25 10:30:00 Elke Eichelmann Data collected. Checked sonic boom angle. Replaced faulty sonic cable.
East End (42) 2016-02-11 11:00:00 Patty Oikawa Swapped LI7500, lots of cattail fuzz
East End (28) 2016-01-28 12:45:00 Joe Verfaillie A Quick data collection, lots of cattail fluff.
East End (12) 2016-01-12 11:10:00 Patty Oikawa Swapped sonic, normal data download, all looked good